Last updated: 29 October 2026. Results transcribed into text from the lab certificate, which is linked below.
This third-party report records test results for a sample of HealthyHey Blueberry Extract submitted by HealthyHey Foods LLP. A laboratory report is evidence of the tests performed, not certification of every claim on the label.
Latest batch: SVVCM12062025M08803, microbiology
Sample described as Blueberry Extract · Batch SVVCM12062025M08803 · Avon Food Lab (Pvt.) Ltd. (NABL TC-11151) · Report AFLPL/260205038 · ULR TC1115126000004639F · Received 5 February 2026, issued 23 February 2026.
| Parameter | Result | Limit printed on report |
|---|---|---|
| Enterobacteriaceae | <10 cfu/g | m=1x10³, M=1x10⁴ cfu/g |
| Salmonella | Absent per 25 g | Absent |
| Listeria monocytogenes | Absent per 25 g | Absent |
Enterobacteriaceae was reported as <10 cfu/g, and Salmonella and Listeria monocytogenes were absent in 25 g. The lab's remark states that the sample conforms to FSSR, 2011 for the limits wherever specified. These results apply to batch SVVCM12062025M08803.
Lab certificate for batch SVVCM12062025M08803 (PDF)
Latest batch: SVVCM12062025M08803, heavy metals
Sample described as Blueberry, voilet coloured powder · Batch SVVCM12062025M08803 · Avon Food Lab (Pvt.) Ltd. (NABL TC-11151) · Report AFLPL/260205049 · ULR TC1115126000003273F · Received 5 February 2026, issued 9 February 2026.
| Parameter | Result | Limit printed on report |
|---|---|---|
| Lead | 0.08 mg/kg | 2.5 mg/kg max |
| Arsenic | 0.14 mg/kg | 1.1 mg/kg max |
| Copper | 7.58 mg/kg | 30.0 mg/kg max |
| Cadmium | BQL (LOQ 0.05 mg/kg) | 1.5 mg/kg max |
| Tin | BQL (LOQ 0.3 mg/kg) | 250 mg/kg max |
| Mercury | BQL (LOQ 0.05 mg/kg) | 1.0 mg/kg max |
| Methyl Mercury | BQL (LOQ 0.1 mg/kg) | 0.25 mg/kg max |
Lead was measured at 0.08 mg/kg, arsenic at 0.14 mg/kg and copper at 7.58 mg/kg, each below the limit printed on the report. Cadmium, tin, mercury and methyl mercury were below the method's quantitation limit. BQL means below the method's quantitation limit, not necessarily absent. The lab's remark states the sample conforms to FSSR 2011. These results apply to batch SVVCM12062025M08803.